Gym Installation
Here we have a gym in St Neots where we have designed a lighting and power layout in collaboration with the customer and architect. 3 compartment dado trunking provides flexibility and futureproofs the installation. Cat 2 louvres have been selected and combined emergency fittings have been located in accordance with BS 5266-1.
Garden Lighting
This is an example of a domestic installation which we have carried out. Led lighting was recommended to the client because of its energy saving benefits over halogen equivalents and the aesthetics of the white light associated with LED's. We can accurately calculate how much money you will save with recommended energy saving products and how long the item will take to pay for itself.
I.C.T. Suite
This is an ICT suite in a local school that we have provided 3 compartment dado trunking and installed power and data at each work station for students. Computer friendly CAT2 lighting has been selected and an interactive "SMART" whiteboard has been introduced.
3 Phase Distribution board and meter
This 3 phase Memshield 3 distrubution board has been installed along with metering equipment in a commercial business unit. The cables are contained within a galvanised steel 4"x4" trunking system for mechanical protection.
Electric Vehicle Charging Point
With electric cars becoming more commonplace we have installed an EVCP at a local college. We are also able to arrange the associated groundworks with installing a EVCP.
This a meeting room of a church in Cambridge town centre. Recessed ceiling lighting has been installed along with power and data around the room. Some of the cabling has been run in between the partition wall and where sockets and data has been required on the wooden cladding, white PVC conduit has been selected.
Here we have a garden at a beautiful home in Stotfold. This job was done for one of our landscape design customers. LED bricklights have been installed in the retaining wall along with pedestal globe lamps on the piers. Both can be switched independently from inside the property.
This particular install was to provide two separate metered tariffs from one single supply. The main fuseboard in the middle is one customers. This feeds the yard lighting and a supply for a small portacabin. The wylex fuseboard on the right hand side feeds another portacabin and is on a seperate tariff.
This was a fuseboard replacement for one of our customers. RCBO protection has been used on all circuits and although its more expensive than a conventional dual RCD board it is less invasive when an earth fault occurs.